PA-4000/PA-96WS PulseAgile® 96-Well Electroporation System

View Data Sheet (122 KB)

The PA-96W 96-Well Array option is used in conjunction with the PA-4000 electroporator to process a large number of samples under various conditions, leading to a clear benefit in time management, variability reduction, and cost savings. As twelve different electrical protocols or even all wells can be pulsed simultaneously, the following applications are no longer on the horizon, they're in your laboratory today.

Proteomic and Functional Genomics
  • Screen DNA libraries
  • Antisense inhibition
  • siRNA inhibition
  • Intracellular monoclonal antibodies
  • Drug target identifier
  • Cell specific responses
  • Gene function and regulation
     
Parameter Optimization
  • Electrical Pulse Waveform
  • Cell density
  • Reagent concentration
Research
  • Vaccine Development
  • Cancer
  • Cell Biology


Click here for Larger Image
  • Precision rectangular (square) wave electroporation
  • Pulse any column, row, or all wells concurrently in a single 96-well plate
  • Reusable electrode array design
  • Computer controlled operation
  • Patented PulseAgile® protocol creation
  • Can be used for standard cuvette electroporation
  • Unlimited protocol storage
  • Log file automatically saved after every run
  • Automatic safety shutdown on arc detection
  • Built-in voltage and current monitors for oscilloscope verification

The Array

A computer controlled pulse switch permits a connection to each row (8 connections) or each column (12 connections) of a 96-well plate for a total of 20 connections on the re-usable electrode array; individual wells are not addressable because of potential high voltage crossover interference. The electrode becomes functional when this array is lowered into a low cost sterile plastic microplate inside of the base holder and high voltage applied.

 

Rectangular (square) Wave

Rectangular wave electroporators have become industry standard because of their ability to increase transfection efficiency while maintaining viability over older and less reliable exponential decay models. Users are given the full ability to adjust parameters for voltage (electric field), pulse width, pulse number, and interval between pulses in an easy to navigate menu system.
 

PulseAgile Protocol

The Cyto Pulse Sciences patented PulseAgile protocol series takes the concept of square wave electroporation one step further: users are given the choice to create multiple protocols with different parameters, called groups, that are run in direct succession of one another. This is generally used to deliver a series of high voltage and short duration pulses first permeabilizing the cell membrane, followed by a series of low voltage and long duration pulses to continue delivery of the transfectant by electrophoresis.

The ultimate goal of creating these types of protocols is to deliver similar transfection efficiencies while retaining an even higher viability than standard four-parameter waves. In particular, published in-vivo applications have repeatedly been found to substantially improve delivery in addition to some ex-vivo applications.
 

System Monitoring

There is no mystery to what's inside the box when all necessary information can be accessed from the outside - Included as standard features are one each of voltage and current monitors ready to attach with an external oscilloscope in order to view real-time pulsing conditions. Using these connections is a true safeguard to know exactly how the applied waveform reflects the programmed waveform, so you never again have to wonder if your protocol ran as intended.

In addition, information relevant to each executed protocol is automatically saved as a log file, including magnified voltage levels of all pulses.
 

Fault Detection

All Cyto Pulse Sciences equipment is designed to withstand extreme user conditions. In the event of a fault, advanced control circuitry immediately detects the source of any problem and proceeds to halt the system to prevent permanent damage. The safety of Cyto Pulse customers is our number one priority.

  • Electrode Interlock – improperly attached cuvettes or electrodes will cause the protocol start function to be disabled until corrected
  • External Fault – extremely low output load arcs will cause high voltage to be turned off and a fault screen to be displayed
  • Internal Fault – damaged internal system components will cause high voltage to be turned off and fault screen to be displayed
     

Example Transfections

 

Specifications

General  
      Pulse Waveform Rectangular (Square)
      Interface Windows Software
      Electrode Reusable electrode array, Cuvette, In-vivo
Protocol  
      Pulse Amplitude HV Mode 20 - 1100 volts @ 5 volt step
      Pulse Amplitude LV Mode 20 - 400 volts @ 2 volt step
      Pulse Amplitude Accuracy ±5%
      Max E-Field (5.4 mm array) 2 kV/cm
      Pulse Duration 0.001 - 100 ms (<300 volts)
0.001 - 40 ms (<400 volts)
0.001 - 20 ms (<500 volts)
0.001 - 1 ms (<1100 volts)
      Pulse Interval 0.125 - 400 sec
      Number of Pulses 1 - 99
      Number of Groups 1 - 40
      Protocol Arrangement Column 1-12
Row A-H
All Wells
      Polarity Reversal Yes
Safety / Monitoring  
      Electrode Interlock Yes
      Arc Control Yes
      Pulse Voltage Monitor BNC Output
      Pulse Current Monitor BNC Output
Electrical  
      AC Line 100 - 240 VAC 50/60Hz
Physical  
      High Voltage Output 23-pin HV Connector
      Computer Control RS232
      Dimensions PA-4000
12.6" x 11.8" x 8.2"
(32 cm x 30 cm x 20.8 cm)

PA-96W
12.6" x 11.8" x 4.7"
(32 cm x 30 cm x 11.9 cm)
      Weight PA-4000
23 pounds (11 kg)

PA-96W
11 pounds (5 kg)


Included in the System

PA-4000 PulseAgile® Advanced Rectangular Wave Electroporator
PA4-SW PulseAgile Application Software
PA4-UMAN PA-4000 Users Manual
CE-20 Cuvette Holder
CUV-M Cuvette Multi-pack set of 5 each: 1 mm, 2 mm, 4 mm
CS-L-XX IEC Line Cord, Serial cable, XX=country
PA-96W PA-96W Programmable Pulse Switch
PA-96W-UMAN PA-96W Users Manual
96W-A Electrode Array for 96-Well Plate
96W-B 96 Well Base for Electrode Array
96W-P 96 Well Polypropylene Plate, square well, flat bottom, 5 each (not sterile)


Ordering

PA-4000/PA-96WS PulseAgile® Advanced 96 Well Electroporation System


 

Cyto Pulse Sciences, Inc.
810 Cromwell Park Drive, Suite T
Glen Burnie, MD 21061
410-787-1890
Laboratory Products  |  Protocol  |  Resources  |  Ordering  |  Contact
Commercial and Clinical Technology

Copyright © 1999-2007 Cyto Pulse Sciences, Inc. All rights reserved