Cuvettes |
| |
| Cyto Pulse Sciences cuvettes are where superior quality meets the requirements of stringent laboratory budgets. With a maximum allowable electric field of 25 kV/cm, these individually wrapped and sterilized cuvettes are immediately ready to process any given cell line, whether it be mammalian, yeast, bacteria, plant, insect, or so on. In addition, three different gap widths of 1 mm, 2 mm, and 4 mm are available to accommodate the various needs of research for cell capacity and desired electric field. Cyto Pulse cuvettes are intended for single use only. |
 |
| |
|
- Compatible with all industry-standard electroporation systems
- Polished aluminum plates guarantee uniform pulse delivery
- Individually sealed and gamma irradiated for absolute sterility
- 2% electrode gap tolerance ensures high transfection consistency
- Easy to handle rounded caps, color-coded for quick identification
- Precision molded polycarbonate prevents undesirable leaking
- Clear case design for sample visibility
|
| Model Number |
Gap Width |
Cap Color |
Minimum Volume |
Maximum Volume |
Qty |
| CUV-01 |
1 mm |
White |
20 µl |
100 µl |
50 |
| CUV-02 |
2 mm |
Blue |
40 µl |
360 µl |
50 |
| CUV-04 |
4 mm |
Red |
80 µl |
670 µl |
50 |
Cuvette Holder |
 |
 |
 |
 |
Cyto Pulse's heavy-duty electroporation cuvette holder will operate with all major cuvette manufacturers, although Cyto Pulse cuvettes are recommended for best results. The insertion mechanism is notched to prevent incorrect cuvette positioning and only upon full insertion will high voltage become enabled to pulse. A large plastic barrier surrounds the cuvette field to completely block any contact with the electrodes. |
 |
| Model Number |
High Voltage Connector |
Comment |
| CE-20 |
MHV |
Standard Holder |
| CE-24 |
Banana Plug |
Used with PA-201 Option for Reverse Polarity |
 |
 |
| |
96-Well Electroporation |
| |
| The PA-96W electrode system consists of a gold-plated array, a polystyrene microplate, and a base holder design. The array is inserted into the base along with a disposable square-well microplate and brought together to form the electrode, significantly reducing running costs when compared to a disposable 96-Well metal electrode. Array cleaning by alcohol allows approximately 50 uses. |
 |
| Model Number |
Description |
| 96W-A |
96-Well array, 5.4 mm gap, 200-400 µl volume, 50 uses |
| 96W-B |
96-Well base, holds Array and Microplate |
| 96W-P-N10 |
Microplate, non-sterile, 10 pack |
| 96W-P-N50 |
Microplate, non-sterile, 10 pack x 5 |
| 96W-P-S10 |
Microplate, sterile, 10 pack |
| 96W-P-S50 |
Microplate, sterile, 10 pack x 5 |
| Model Number |
Gap Width |
Minimum Volume |
Maximum Volume |
| FE-C25/400 |
2.5 |
100 µl |
350 µl |
| FE-C25/800 |
2.5 |
100 µl |
750 µl |
| FE-C20/1000 |
2 |
100 µl |
1000 µl |
| FE-10 |
Coaxial Electrode Holder |
|